vPad-IN Infant Incubator & Radiant Warmer Testing System - Datrend Systems

vPad-IN Infant Incubator & Radiant Warmer Testing System

The Next Generation vPad-IN Infant Incubator & Radiant Warmer Testing System

  • Tests to IEC 60601-2-19, 2-20 and 2-21
  • Follows both Edition 1 and Edition 2 of Standard
  • Built on the Vision-Pad platform to give you greater flexibility and scalability
  • Wireless control of tests within incubator
  • Changes to test can be made without disturbing heat environment
  • Measures all parameters automatically following user-defined protocols
  • Results can be automatically merged with Electrical Safety test results

vPad-IN is a next generation infant incubator and radiant warmer testing system that meets the requirements of the IEC Standards for Incubators (IEC 60601-2-19), Infant Transport Incubators (IEC 60601-2-20) and Radiant Warmers (IEC 60601-2-21).

vPad-IN has all the functionality and scalability that you have come to expect from Vision-Pad Technology products. Parameters are sensed inside the incubator environment and results are transmitted wirelessly to a 10.1″ Android tablet for analysis and display. Test parameters and test protocols can be modified without disturbing the equilibrium of the heated environment, thereby minimizing test times.

Back to Products
  • Description
  • Additional information

Description

vPad-IN Infant Incubator & Radiant Warmer Testing System

FEATURES

Compatible with closed, forced air convection incubators, and open, radiant infant warmers.

  • Simultaneously measures humidity, airflow, sound, and 6 different temperatures
  • Tests are carried out in accordance with IEC 60601-2-19, IEC 60601-2-20, and IEC 60601-2-21
  • All sensors are independently movable, to be placed in positions required by the Standard
  • Sound level measurements may be taken outside the incubator for external alarm test
  • Results can be automatically merged with vPad Electrical Safety test results
  • Optional precision controlled heater can accurately test body temperature sensors
  • 2 year warranty.

Additional information

Brand

Datrend

Related products

  • Netech EXPMT 2000 External Pacemaker Analyser

    EXPMT 2000 External Pacemaker Analyser

    Show Details
  • EndobenchXT™ Portable Scope Tester

    EndobenchXT™ Portable Scope Tester

    Show Details
  • Datrend Oxitest Plus7 Sp02 Patient Simulator

    Oxitest Plus7- Sp02 Simulator

    Show Details
  • Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyser - Netech Biomedical Instruments - Chivaune Technologies

    Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyser

    Show Details
© Copyright 2022 - Chivaune Technologies | sales@chivaune.com.au | + 617 3157 8684 | +614 1211 2514
  • LinkedIn
  • Facebook
Microsim COS Cardiac Output Simulator Netech Microsim COS - Cardiac Output Simulator - Chivaune Technologies Australia Fermitron Tympanic Thermometer Tester Tympanic Thermometer Tester
Scroll to top
Product Enquiry

  • Enquiry for: vPad-IN Infant Incubator & Radiant Warmer Testing System