Delta 1600 Defibrillator AED Analyser- Netech Biomedical Instruments - Chivaune Technologies Australia and New Zealand

Delta 1600 Defibrillator AED Analyser

Delta 1600 Defibrillator AED Analyser 

The Delta 1600 Automated External Defibrillator (AED) Analyser by Netech is a precision, compact, and battery operated instrument for testing automated external defibrillators (AEDs). The Delta 1600 simulates various cardiac waveforms to ensure that the AED can detect, analyze and audibly advise shock. In addition to the shock advisory test, Delta 1600 measures discharged energy of the AED, thereby ensuring that the AED complies with specified requirements.

The dedicated function keys and menu driven display on the unit makes it simple for operation. The Delta 1600 has a built-in load resistance of 50 ohms to simulate the human body impedance.

To establish electrical connection between the AED and the Delta 1600, manufacturer specific interface cables (contact Netech Sales for custom cables) are required. The interface cable must be connected between the AED and input jacks of Delta 1600. Once the AED is discharged, Delta 1600 samples the pulse, calculates and displays the delivered energy.

The Delta 1600 is the ideal tester for AEDs that are used in ambulances, police cars, sports stadiums, aircraft, schools, malls, and other remote locations.

Use of the 610-Paddle Adapter allows the Delta 1600 to be used on AEDs with reusable paddles.

The Delta 1600 Defibrillator Analyser comes complete with a set of insulated banana jacks and a soft carrying case.

 

For other Netech Biomedical Testing Instruments – Delta 3300 Defibrillator/Pacemaker Analyser 

Back to Products
  • Description
  • Additional information

Description

Delta 1600 Defibrillator AED Analyser Features:

  • Unique, one-of-a kind instrument for testing all AEDs including Pulsed (Schiller AEDs)
  • Compact, lightweight and easy-to-use
  • Auto Function – Eliminates multiple discharges
  • Large backlit Graphics Display
  • Multiple Arrhythmia simulations
  • 7.4 Volt Li-Ion Rechargeable battery
  • 2 year warranty.

Additional information

Brand

Netech

Specifications

Energy Output:
Maximum Energy : 500 J
Display Resolution : Based on Auto Range
Resolution : 1 J
Accuracy : ±1 % of reading ± 1

Load Resistance:
50 ohms ±1 %; non-inductive (< 1 μH)
Sampling Time : 20 uS
Measurement Time Window : 60 ms
Pulse Width : 60 ms

Patient Simulator:
Waveform Simulation: ECG (NSR),
ECG Rate: 60, 70, 80, 90, 100, 110, 120,
130, 140, 150, 160, 170, 180, 190, 200,
220, 240. BPM
Accuracy: ± 1%
Waveform Amplitude: ECG (AMP)
ECG Amplitude:1.0, 2.0, 3.0, 4.0 mV
Accuracy: ± 5% peak to peak

Arrhythmia Selections:
(Shock advisory waveforms)
Ventricular Fibrillation Coarse (VFBC)
Ventricular Fibrillation Fine (VFBF)
Ventricular Tachycardia (VTAC)
Atrial Fibrillation (AFIB)

Temperature Range:
Operating : +15°C to +35°C
Storage : 0°C to +50°C.

Display:
Type: LCD with LED backlit
Graphics displ

Power:
7.4 Volt Li-Ion Rechargeable Battery
100-230 VAC input 8.5V Battery Charger

Housing:
High impact ABS plastic
enclosure

Dimensions:
D x W x H :10.25 x 6.25 x 2.5 Inch

Related products

  • Phase 3 VLM Defibrillator/Pacer Analyser - Datrend

    Phase 3 VLM Defibrillator/Pacer Analyser

    Show Details
  • Netech Minisim Advanced Patient Simulator - Chivaune Technologies Australia

    MiniSim Advanced Patient Simulator

    Show Details
  • Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyser - Netech Biomedical Instruments - Chivaune Technologies

    Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyser

    Show Details
  • Netech Minisim EEG Simulator

    Minisim EEG Simulator

    Show Details

  • Chivaune Technologies Pty Ltd
  • +617 3157 8684
  • sales@chivaune.com.au

What We Do

Biomedical Test Equipment
Test Equipment Calibration
AV Solutions

Quick Links

Home
About Us
News
Contact Us

© Copyright 2026 - Chivaune Technologies
  • LinkedIn
  • Facebook
EndobenchXTB™ Image Quality Tester (Bench-mount model) EndobenchXTB™ Image Quality Tester (Bench-mount model) EndobenchXT™ Portable Scope Tester EndobenchXT™ Portable Scope Tester
Scroll to top

"*" indicates required fields

Limited Online Selection – Full Range Available!


While we currently have a select range of products available on our website, we have access to the full catalogue from our trusted suppliers. If you’re looking for something specific that you don’t see here, complete your details below for access to our supplier catalogues.

How to Order:

    1. Contact Us: Use our Contact Page or give us a call at +617 3157 8684.
    2. Provide Details: Let us know what you’re looking for, and we’ll check availability. If you're not sure which specific product you need - we can help guide you.
    3. Order Processing: Once we confirm availability, we’ll process your order and arrange delivery.
We’re happy to help you find exactly what you need.
Name*
Brands of interest *
Consent
Product Enquiry

  • Enquiry for: Delta 1600 Defibrillator AED Analyser