• LinkedIn
  • Facebook
  • 0Shopping Cart
Chivaune Technologies
  • Home
  • Test Equipment
      • Defibrillator and Pacemaker Analysers
      • Cardiac Output Simulators
      • ECG Simulators
      • EEG Simulators
      • Electrical Safety Analysers
      • Endoscope Testing Solutions
      • ESU Analysers
      • Flow Analysers
      • Foetal Heart Simulators
      • Incubator Testing
      • Infusion Device Analyser
      • Multi-Parameter Patient Simulators
      • NIBP Simulators
      • Patient Simulator Bundles / Kits
      • Pressure and Vacuum Meters
      • Sp02 Simulators
      • Tympanic Thermometer Tester
      • Ventilator Testing Solutions
      • Ventilator Test Lungs
  • Calibration
  • Simulation
    • Immersive Reality
    • Healthcare Simulation
  • News
  • About
  • Contact
  • Search
  • Menu Menu
Netech Minisim Advanced Patient Simulator - Chivaune Technologies Australia

MiniSim Advanced Patient Simulator

MiniSim Advanced Patient Simulator is a multi-parameter ECG patient simulator designed for testing and verifying the performance of patient monitoring systems quickly and easily. This microprocessor based instrument is menu driven by the soft touch keypad and intuitive LCD display.

It simulates ECG, arrhythmia, blood pressure, respiration, and temperature as well as performance waveform including sine, triangular, pulse and square wave.

Full 12 lead ECG simulation with 14 user selectable rates from 30 to 350 BPM and 14 user selectable amplitudes from 0.15 to 5 mV are all provided by the MiniSim 1000. Sine, Square, and Triangle performance waveforms are simulated with 14 user selectable rates from 0.1 to 100 Hz.

MiniSim 1000 also simulates 45 different arrhythmias including atrial, ventricular, tall T wave, ST elevation, ST depression, myocardial infarction, blocks, pulse, and pacer waveforms. In addition, two invasive blood pressures are simulated with choice of 12 static pressures and 6 dynamic waveforms. Respiration is simulated with 4 rates, 4 baseline impedance, and 4 delta impedance selections. Apnea may be off, continuous, and with either 12 or 32-second apnea bradycardia. Finally, the temperature is available at either 25° and 37° C (77° and 98.6° F).

Powered by a 9-volt alkaline battery with a typical life of 40 continuous hours, MiniSim 1000 provides unmatched choices of patient simulation in an efficient, well-designed package.

Optional pressure and temperature interface cables are available for most manufacturers.

Back to Products
  • Description
  • Additional information

Description

  • 12 Lead ECG
  • 45 Arrhythmias
  • ECG Performance Waveforms
  • 2 Blood Pressure Simulations
  • Respiration / Apnea
  • Temperature
  • Easy to Use
  • Small, Compact Size
  • Menu Driven Operation
  • Large LCD Display
  • Tactile Keypad
  • Battery or AC Powered
  • 1 year warranty.

Additional information

Brand

Netech

Specifications

ECG Rates:  30, 60, 70, 80, 90, 100, 120, 150, 180, 210, 240, 270, 300, and 350 BPM. Accuracy 0.5%
Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II. Lead 1 is 0.6 X Lead II, Lead III is 0.4 X Lead II, and Lead V is the same as Lead II
High Level: 500 X low level output on Lead II
Accuracy: 2% (1-5mV)

Performance Waverforms (PERF)
Sine, Square, Triangle, Pulse
Frequencies: 0.1 to 0.9 in 0.1 Hz steps
1.0 to 9.0 in 1.0 Hz steps
10 to 100 in 10 Hz steps
Accuracy: 1%
Amplitudes: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II
Pulse: 20 ms pulse of 1mV amplitude repeated at 4 second intervals

R Wave Detection (RWD)
Widths: 10, 40, 50, 60, 70, 80, 90, 100, 110, and 120 ms.
Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mV on Lead II.

Pacer (PCR)
AP: Atrial Pacer set at 70 BPM
ASP: Asynchronous Pacer
QRS Amplitudes: 1 mV
PCR: Pacer pulses alone
Pacer Widths: 0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 ms
Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV
VP: Ventricular Pacer set at 70 BPM
AVP: Atrial Ventricular Pacer set at 70 BPM. QRS Amplitude: 1 mV
Pacer Amplitude: -2mV

Respiration
Baseline Impedance: 250, 500, 750, and 1000 Ohms
Delta Impedance: 0.1, 0.5, 1.0, and 1.5 Ohms
Accuracy: 20%
Rates: 15, 30, 60, and 120 BPM
Accuracy: 1%
Apnea: Off, continuous, 12 seconds and 32 seconds
Lead Configuration: Leads I and II

Blood Pressure
Impedance: 350 Ohms
Excitation: 2 to 16 Volts
Sensitivity: 5mV/V/mmHg
Static: 0, 5, 10, 20, 25, 30, 40, 50, 100, 150, 200, and 300 mmHg
Dynamic: 50/10, 60/20, 70/30, 80/40, 100/60, and 120/80 mmHg. Dynamic waveforms track all NSR rates

Temperature
Compatibility: YSI 400 and 700 Series.
Temperature: 25° and 37° C (77° and 98.6° F)
Accuracy: 2% of setting

General:
Power Requirements: One 9 Volt alkaline battery or optional AC adapter
Temperature Requirements: Operating: 15° to 35° C (59° to 95° F); Storage: 0° to 55C (32° to 131° F)
Dimensions: 5.5"x 3.5" x 1.5" (13.9 x 8.9 x 3.8 cm)
Dimensions: 5.5"x 3.5" x 1.5" (13.9 x 8.9 x 3.8 cm)

Related products

  • Delta 1600 Defibrillator AED Analyser- Netech Biomedical Instruments - Chivaune Technologies Australia and New Zealand

    Delta 1600 Defibrillator AED Analyser

    Show Details
  • Digimano 2000 Digital Pressure and Vacuum Gauge

    Digimano 2000 Digital Pressure and Vacuum Gauge

    Show Details
  • Netech Minisim 1000 ECG Simulator - Chivaune Technologies Australia

    Minisim 1000 ECG Simulator

    Show Details
  • Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyser - Netech Biomedical Instruments - Chivaune Technologies

    Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyser

    Show Details
© Copyright 2022 - Chivaune Technologies | sales@chivaune.com.au | + 617 3157 8684 | +614 1211 2514
  • LinkedIn
  • Facebook
vPad-PS Multi-Parameter Patient Simulator vPad-PS Multi-Parameter Patient Simulator Netech Minisim 1000 ECG Simulator - Chivaune Technologies Australia Minisim 1000 ECG Simulator
Scroll to top
Product Enquiry

  • Enquiry for: MiniSim Advanced Patient Simulator