• Link to LinkedIn
  • Link to Facebook
  • About
  • News
  • Contact
  • Shopping Cart Shopping Cart
    0Shopping Cart
Chivaune Technologies
  • Biomedical Test Equipment
      • Cardiac Output Simulators
      • Defibrillator and Pacemaker Analysers
      • ECG Simulators
      • EEG Simulators
      • Electrical Safety Analysers
      • Endoscope Testing Solutions
      • ESU Analysers
      • Flow Analysers
      • Foetal Heart Simulators
      • Incubator Testing
      • Infusion Device Analyser
      • Multi-Parameter Patient Simulators
      • NIBP Simulators
      • Patient Simulator Bundles / Kits
      • Pressure and Vacuum Meters
      • Sp02 Simulators
      • Tympanic Thermometer Tester
      • Ventilator Testing Solutions
      • Ventilator Test Lungs
  • Calibration
  • Lung Simulator
  • AV Solutions
    • SIMStation
  • Catalogues
  • Enquire Today
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu
Netech Minisim 1000 ECG Simulator - Chivaune Technologies Australia

Minisim 1000 ECG Simulator

MiniSim-1000 Arrhythmia Simulator is a powerful yet basic patient simulator in a compact case. It is designed for testing the performance of all ECG monitoring instrumentation quickly and easily. 300his comprehensive microprocessor-based instrument is menu driven using the tactile feel keypad and easy-to-follow LCD display.

The MiniSim-12 provides full 12 lead ECG simulation with 14 user selectable rates ranging from 30 to 350 BPM, and 14 user selectable amplitudes from 0.15 to 5 mV. The performance waveform includes Sine, Square and Triangle . 14 user-selectable waveform rates from 0.1 to 100 Hz and amplitudes from 0.15 millivolt to 5 millivolts.

The instrument is also designed to simulate 45 different arrhythmias including atrial, ventricular, tall T wave, ST elevation, ST depression, myocardial infarction, blocks, pulse and pacer waveforms.

MiniSim 1000 Arrhythmia Simulator is software upgradable to MiniSim 1000 full function patient simulator including Blood pressure, respiration, and temperature (YSI 400/YSI 700 compatible)

Back to Products
  • Description
  • Additional information

Description

Minisim 1000 ECG Simulator

FEATURES

  • Best Value
  • Easy to Use
  • Compact Size
  • Menu Driven operation
  • Large LCD Display
  • Tactile Keypad
  • Battery or AC Operation
  • 1 year warranty.

 

Additional information

Brand

Netech

Specifications

ECG: 12 leads with independent outputs referenced to RL
NORMAL SINUS RHYTHM (NSR)
ECG Rates: 30, 60, 70, 80, 90, 100, 120, 150, 180, 210, 240, 270, 300, and 350 BPM. Accuracy 0.5%.
Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II. Lead 1 is 0.6 X Lead II, Lead III is 0.4 X Lead II, and Lead V is the same as Lead II.
High Level: 500 X low-level output on Lead II.
Accuracy: 2% (1-5mV).
PERFORMANCE WAVEFORMS (PERF)
Sine, Square, Triangle, Pulse
Frequencies: 0.1 to 0.9 in 0.1 Hz steps.1.0 to 9.0 in 1.0 Hz steps.10 to 100 in 10 Hz steps.
Accuracy: 1%
Amplitudes: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II.
Pulse: 20 ms pulse of 1mV amplitude repeated at 4-second intervals.
R WAVE DETECTION (RWD)
Widths: 10, 40, 50, 60, 70, 80, 90, 100, 110, and 120 ms.
Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mV on Lead II
PACER (PCR)
AP: Atrial Pacer set at 70 BPM
ASP: Asynchronous Pacer- Ineffective Pacing
QRS Amplitudes: 1 mV
PCR: Pacer pulses alone
Pacer Widths: 0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 ms
Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV
VP: Ventricular Pacer set at 70 BPM
AVP: Atrial Ventricular Pacer set at 70 BPM
QRS Amplitude: 1 mV.Pacer Amplitude: -2mV

Related products

  • vPad rugged 2 electrical safety analyser Datrend Systems - biomedical test equipment Australia and New Zealand

    vPad-Rugged 2 Electrical Safety Analyser

    Add to cart Add to cart Show Details Show Details Show Details
  • SC-4 SimCube® NIBP Simulator - by Pronk Technologies distributed by Chivaune Technologies in Australia

    SC-4 SimCube® NIBP Simulator

    Add to cart Add to cart Show Details Show Details Show Details
  • Fermitron Tympanic Thermometer Tester

    Tympanic Thermometer Tester

    Add to cart Add to cart Show Details Show Details Show Details
  • IMT Analytics Biomedical Test-Set 'Ventilation' PF-300 - Chivaune Technologies Australia

    Biomedical Test-Set “Ventilation” PF-301 VAC

    Add to cart Add to cart Show Details Show Details Show Details

  • Chivaune Technologies Pty Ltd
  • +617 3157 8684
  • sales@chivaune.com.au

What We Do

Biomedical Test Equipment
Test Equipment Calibration
AV Solutions

Quick Links

Home
About Us
News
Contact Us

© Copyright 2026 - Chivaune Technologies
  • Link to LinkedIn
  • Link to Facebook
Link to: MiniSim Advanced Patient Simulator Link to: MiniSim Advanced Patient Simulator MiniSim Advanced Patient SimulatorNetech Minisim Advanced Patient Simulator - Chivaune Technologies Australia Link to: Microsim COS Cardiac Output Simulator Link to: Microsim COS Cardiac Output Simulator Netech Microsim COS - Cardiac Output Simulator - Chivaune Technologies AustraliaMicrosim COS Cardiac Output Simulator
Scroll to top Scroll to top Scroll to top

"*" indicates required fields

Limited Online Selection – Full Range Available!


While we currently have a select range of products available on our website, we have access to the full catalogue from our trusted suppliers. If you’re looking for something specific that you don’t see here, complete your details below for access to our supplier catalogues.

How to Order:

    1. Contact Us: Use our Contact Page or give us a call at +617 3157 8684.
    2. Provide Details: Let us know what you’re looking for, and we’ll check availability. If you're not sure which specific product you need - we can help guide you.
    3. Order Processing: Once we confirm availability, we’ll process your order and arrange delivery.
We’re happy to help you find exactly what you need.
Name*
Brands of interest *
Consent
Product Enquiry

  • Enquiry for: Minisim 1000 ECG Simulator